Cooling Operation of the New Winter Palace of Justice

plants air conditioning are handled by the "A2A Calore & Services" which is responsible for the operation on behalf of the Municipality of Brescia. The employees of the 'A2A Calore & Services "are in a stable manner at guaranteeing operations. The management of the entire air conditioning system is done through software that can control the temperature of each room in the manner described below. Is set to a certain temperature, the same for all the palace and through the probes placed in each local environment that is maintained. Please
therefore, to the extent possible not to change the setting of the fan-coil and can not open the windows, because all the rooms are equipped with forced air circulation.

Malfunctioning MUST BE SENT VIA EMAIL TO WRITING OFFICE (Geom. SQUARE) AND SENT OUT BY OFFICERS RESPONSIBLE FOR JUDICIAL OFFICES OR persons delegated by them.

The winter heating systems have been activated with effect from 15.10.2009 and, to date, no major problems were reported. The timing of the regime necessary to achieve the expected weather conditions were very fast and therefore were easy to arrange the times and temperatures of service delivery which summarized below:
- Monday to Friday from 8:00 to 18:00
- Sabato dalle ore 8:00 alle ore 14:00
- Domenica e festivi spento
- Temperatura ambiente prevista 21° ±1°C
Si precisa che le temperature impostate previste dall’art 4 c.1 D.P.R. 412/93 e DPR 551/99 nella Ns. zona climatica per edifici classificati E.2. è di 20° c + 2

Riportiamo di seguito una brevissima sintesi delle principali caratteristiche costruttive dell’impianto:

Fan-coils

L’impianto fan coils ha lo scopo di riscaldare o raffrescare gli ambienti. Negli uffici, nei corridoi e nelle aule udienze , i fan-coils sono integrati negli arredi posti sotto i serramenti. Nei corridoi interni e nelle stanze “a disposizione”, are the traditional places on the ground. Each fan coil is equipped with a control panel Power ON / OFF switch and fan speed ( selectors must remain with the ON position and speed II).
The temperature is automatically adjusted every office in the middle of a room sensor which acts directly on the two-way modulating valve and the fan on each fan coil.
The principle of operation in winter structure is as follows:
- when the ambient temperature rises above 21.5 ° C on the modulating valve reduces the flow of water fan coil units (up to complete closure of the valve air comes out at room temperature so do not heated - for about 1 minute) to complete closure of the valve is automatically switched off the ventilator.
- when the temperature falls below 20.5 ° C around the valve and the fan resume their normal cycle.
In order to avoid disruptions, will block the control panels of the fan coils installed in the corridors and in areas of public access.

radiator systems

The radiator system is designed to heat the rooms. All toilets are equipped with radiators in ghisa.L 'air extraction is provided by centralized extraction system placed on the roof of the building (roof exhaust units).

Impianto di termoventilazione

L’impianto di termoventilazione ha lo scopo di riscaldare gli ambienti e garantire i necessari ricambi di aria. Gli archivi ed i depositi dei due piani interrati sono dotati di armadi di termoventilazione locali. Ogni macchina è dotata di presa aria esterna collegata ad una canalizzazione che giunge sino in copertura. Ogni termoventilatore è comandato da sonda ambiente e regolatore a microprocessore.
Si prega di dare la massima divulgazione alle presenti indicazioni al fine di consentire il funzionamento dell’impianto in maniera ottimale.